Hadco Lighting: MUL4 AS7 Pathlyte
Description Mushrooms offer classic styling and a graceful appearance making them suitable for most applications. Designed as a spread light, these luminaires produce a uniform light pattern with no objectional glare. Finishes are available in antiqued verde, bronze, sienna, speckled stone, black and natural cast bronze. Specifications HOUSING: Die-cast aluminum. Stem is extruded aluminum. Roof has dual stainless steel hinge with stainless steel spring-lock for tool-less entry and relamping. ½" NPS male threads to screw onto accessory mounting stake or junction box, sold separately. FINISH: Thermoset polyester powdercoat is electrostatically applied after a five-stage conversion cleaning process and bonded by heat fusion thermosetting. Laboratory tested for superior weatherability and fade resistance in accordance with ASTM B117 specifications. OPTICAL ASSEMBLY: Spun aluminum reflector with white thermoset powdercoat. Frosted tempered glass sprinkler shield includes top and bottom silicone gaskets for tight seal. LAMPING: 20W maximum T3 bi-pin lamp. Lamp is included with fixture. Lower wattage lamps are acceptable. ELECTRICAL ASSEMBLY: Bi-pin socket type (G4) with 250° C high temperature teflon coated wire leads. 12 Volt fixture is pre-wired with 3-ft pigtail of 18-2 AWG, 105° C, SPT-1W wire. Low voltage quick connector, catalog #LVC3 included for easy hook-up to the low voltage supply cable, not included. 12 Volt system requires remote transformer, not included. WARRANTY: Three-year limited warranty. CERTIFICATIONS: ETL listed to U.S. safety standards for wet locations. cETL listed to Canadian safety standards for wet locations. Manufactured to ISO 9001:2008 Standards. Height : 19 1/2" (495mm) Width: 5 1/16" (129mm) Max. Weight: 1.9 lb.
- The components of this light are the Roof Latch and the half inch NPS fitter. The following are the standard installation instructions.
Step 1. Make sure power is turned OFF before installing or servicing the fixture.
Step 2. This fixture must be mounted to a junction box or mounting stake that is UL listed for low voltage and wet locations. Mounting stakes S1, S6, S7, S8, and TS375-12 may be used.
Step 3. Route the wires from the fixture through the stem (order separately) and thread stem into fixture.
Step 4. Insert fixture wire through 1/2" NPS hole in stake cap and screw fixture into cap.
Step 5. Wire fixture to supply cable with low voltage connector (included) by following the instructions below.
Step 6. Attach stake cap to stake, being careful not to pinch wire.
Step 7. Remove the (screws that hold the roof to the cage and access the socket. Install The lamp and reassemble fixture. Remember never to touch the lamp with bare hands as hand oil will damage the lamp.
Step 8. Finally Turn power ON. The following lamps may be used with this fixture 20 watt t3 halogen bi-pin 10 watt t3 halogen bi-pin 5 watt t3 halogen bi-pin For more information feel free to contact us.
LOW VOLTAGE CABLE CONNECTOR INSTRUCTIONS
Low voltage cable connector to be used with 10 or 12 gauge supply cable and 18 gauge fixture cable. Philips recommends using SPT-3 water resistant (marked "WA", "W" or similar marking) supply cable such as our SCW500- 10/BSCW500-10 or our SCW100-12/BSCW100-12. Philips also recommends ordering the entire system, which includes the power console (maximum 25 Amps, 15 Volts per circuit), fixture(s) (low voltage cable connector included) and supply cable to ensure proper installation and operation.
When using our supply cable, it can be laid on top of the ground, placed under "ground cover" (that is, shallow burial less than 6 inches or 15.2 cm deep), or directly buried in accordance with the NEC. If not using our cable, per UL 1838-Standard for Low Voltage Landscape Lighting Systems, the secondary cable must be SPT-3 or suitable for wet locations, sunlight resistant and direct burial per UL 493 and sized per UL 1838, and it must be buried less than 6 inches (15.2 cm).
Philips recommends a minimum depth of 4 inches when burying in the lawn to prevent damage from aerators or other lawn plugging equipment. The 18 gauge fixture cable (provided with fixture) must be protected by routing in close proximity to the fixture or secured to a building structure such as a house or deck. The fixture cable must be cut off so that it is connected to the low voltage cable connector within 6 inches (15.2 cm) of the fixture or the building structure. When making an underground connection to the 10 or 12 gauge supply cable (not provided), the fixture cable must not be buried more than 6 inches (15.2 cm). WARNING-Mount the luminaire in or on non-combustible mounting surfaces only.
WARNING-Risk of Electric Shock. Install all luminaires 10 feet (3.05m) or more from a pool, spa, or fountain. 1. Connect the supply cable to the terminals on the power console (transformer) and turn ON. 2. Disassemble the connector by removing the Phillips head screw. 3. Inspect the connector to ensure the prongs are straight. If the prongs are bent, straighten with pliers. 4. Insert the end of the fixture cable into the square opening in the connector body. Bend wire over so that wire is laying in
the recess marked '18 GA'. This will help hold the wire in place while performing steps 5 and 6. Only 2-wire cable is to be
used and the common (smooth) wire and hot (ribbed) wires must be oriented as shown. 5. Press the supply cable into the recess marked '10,12/2 GA' on the connector body. Again the common (smooth) wires
and the hot (ribbed) wires must be oriented as shown. 6. Press the connector cover onto the connector body, making sure the screw holes line up with each other. 7. Assemble the connector by tightening the Phillips head screw. NOTE: Make sure the metal prongs in the connector
pierce all 4 wires; the fixture will light as the prongs pierce the wires.